06Fittings & accessories
Fittings & Accessories
Everything between the straight sections: fittings that change direction and width, covers, splice plates and fasteners, and the brackets, arms and hangers that carry the run. Specify each item with the tray size, material and finish it belongs to.

- Fittings
- 6types
- Covers
- 2types
- Joints & fasteners
- 4types
- Supports
- 5types
Materials & finishes
Sales engineering · +86 130 2055 8968 · arya@globalcabletray.com
01Catalogue
17 accessories for a complete run.
Specify each item with the tray width and height, material and finish of the run it belongs to.

Fittings Horizontal bend 90°
Turns the run in the horizontal plane.

Fittings Covered bend 90°
90° bend with matching cover for enclosed trunking runs.

Fittings Horizontal tee
Branches one run into two directions at the same level.

Fittings Horizontal cross
Four-way junction where two runs intersect.

Fittings Reducer
Joins trays of different widths.

Fittings End cap
Closes the end of a run.

Covers Straight cover
Flat cover for ladder and perforated runs — protection from falling objects and sunlight.

Covers Trunking cover
Flanged cover for solid-bottom trunking.

Joints & fasteners Splice plate
Joins straight sections, bolted through the side walls.

Joints & fasteners Splice plate kit
Splice plates supplied with their bolts, nuts and washers.

Joints & fasteners Bolts, nuts & washers
Hex bolts, nuts, flat and spring washers.

Joints & fasteners Earthing bracket
Bonding point for the protective earth conductor along the run.

Supports Hold-down clamp
Fixes the tray to a support channel without drilling.

Supports Cantilever arm
Strut-profile arm projecting from a wall or column to carry the tray.

Supports Wall bracket
Base-plate bracket with gusset for wall-mounted runs.

Supports Trapeze hanger
Hanger frame that carries the tray from ceiling rods.

Supports Threaded rod
Hanger rod with nuts for ceiling suspension.
02Materials & finishes
Choose the finish by the site, not the catalogue.
Fittings and supports are supplied in the material and finish of the run they belong to.
01
Pre-galvanized steel
Continuously hot-dip galvanized coil, slit, punched and formed after coating.
Use · Dry interiors: offices, data halls, plant rooms.
ISO 9223C1–C2
SGS (IEC 61537): pre-galvanised class 1, zinc 5.6 μm — ladder, perforated and trunking series. Also the base sheet for our powder-coated trays.
02
Hot-dip galvanized (after fabrication)
Finished sections are dipped in molten zinc after punching and welding, so cut edges, holes and welds are coated.
Use · Outdoor racks, humid process halls, car parks, tunnels.
ISO 9223C3–C4
SGS (IEC 61537): post-galvanised class 8, zinc 85 μm — ladder, perforated and trunking series.
03
ZAM · zinc-aluminium-magnesium
Steel with a zinc-aluminium-magnesium coating, formed after coating. The coating protects cut edges and holes as it weathers.
Use · Humid interiors and sheltered outdoor runs where pre-galvanized sheet is not enough.
ISO 9223C3–C4
04
Electrostatic powder coating
Five-stage pretreatment (degreasing, pickling, surface conditioning and phosphating, multi-stage pure-water rinse, drying at 80–100 °C for 30 min), electrostatic application at 50–100 kV, curing at 180–220 °C for 20–30 min.
Use · Interiors where circuits are colour-coded or appearance matters.
ISO 9223C1–C3
Each batch is sample-tested for cross-cut adhesion, impact and salt spray.
05
Duplex · HDG + powder coat
Powder topcoat over hot-dip galvanizing: barrier protection on top of sacrificial zinc.
Use · Coastal and outdoor runs that also need a colour.
ISO 9223C4–C5
06
Stainless steel 304
Austenitic stainless steel — no coating to damage during installation.
Use · Food, pharma, cleanrooms; general outdoor runs away from chlorides.
ISO 9223Hygienic · C3–C4
07
Stainless steel 316
Molybdenum-bearing stainless grade for chloride and chemical exposure.
Use · Ports, offshore-adjacent plants, refineries, wastewater.
ISO 9223C4–C5 · CX
08
Aluminium alloy
Lightweight, non-magnetic alloy with a natural oxide layer.
Use · Weight-sensitive structures and non-magnetic requirements.
ISO 9223C3–C4
04Technical documents
Downloads
Datasheet for this line plus the certificates that apply to it.
Download center- Datasheet · PDF · 2.7 MBFittings & Accessories datasheetRange, materials and finishes · A4 PDF
- CE attestation · PDF · 31 KBCE · Low Voltage Directive attestationUDEM M.2023.206.C88198 · EN 61537:2007
- ISO certificates · PDF · 5.1 MBISO 9001 · ISO 14001 · ISO 45001Huadingsihai · CNAS C256-M · valid to 2028-07-24
Quote · Accessories
List the fittings per run. We quote them with the tray.
Give sizes, quantities and the finish — or send the cable schedule and drawings by email. No prices are shown online; every quotation is itemized.
- +86 130 2055 8968