03Cable tray system
Cable Trunking
A solid base and side walls with an optional cover. Enclosed runs protect control, instrumentation and sensitive circuits from impact, dust and electromagnetic interference; dividers segregate circuits inside one run.

- Width
- 50–800mm
- Height
- 25–200mm
- Thickness
- 1.0–2.5mm
- Standard length
- 3m
- Tested load
- 2,680N/m
- 1.2 m span · SGS
Materials & finishes
Standard · model series
Sales engineering · +86 130 2055 8968 · arya@globalcabletray.com
01Standard series
Trunking series · IEC 61537:2023
Forty-nine models from 50 × 25 to 800 × 200 mm, as listed in the SGS verification reports. Add any row to your RFQ.
Material
Width (mm)
| Model | W (mm) | H (mm) | t (mm) | L (m) | SWL (N/m) | Add to RFQ |
|---|---|---|---|---|---|---|
| HF-Q-C-01A-5025-H8 | 50 | 25 | 1.0 | 3 | 78 | |
| HF-Q-C-01A-6025-H8 | 60 | 25 | 1.0 | 3 | 92 | |
| HF-Q-C-01A-6040-H8 | 60 | 40 | 1.0 | 3 | 368 | |
| HF-Q-C-01A-6050-H8 | 60 | 50 | 1.0 | 3 | 708 | |
| HF-Q-C-01A-8040-H8 | 80 | 40 | 1.0 | 3 | 491 | |
| HF-Q-C-01A-8050-H8 | 80 | 50 | 1.0 | 3 | 946 | |
| HF-Q-C-01A-8060-H8 | 80 | 60 | 1.0 | 3 | 1,280 | |
| HF-Q-C-01A-10050-H8 | 100 | 50 | 1.2 | 3 | 1,100 | |
| HF-Q-C-01A-10060-H8 | 100 | 60 | 1.2 | 3 | 1,350 | |
| HF-Q-C-01A-10080-H8 | 100 | 80 | 1.2 | 3 | 1,450 | |
| HF-Q-C-01A-100100-H8 | 100 | 100 | 1.2 | 3 | 1,710 | |
| HF-Q-C-01A-15050-H8 | 150 | 50 | 1.5 | 3 | 1,180 | |
| HF-Q-C-01A-15060-H8 | 150 | 60 | 1.5 | 3 | 1,410 | |
| HF-Q-C-01A-15080-H8 | 150 | 80 | 1.5 | 3 | 1,570 | |
| HF-Q-C-01A-150100-H8 | 150 | 100 | 1.5 | 3 | 1,820 | |
| HF-Q-C-01A-20050-H8 | 200 | 50 | 1.5 | 3 | 1,230 | |
| HF-Q-C-01A-20060-H8 | 200 | 60 | 1.5 | 3 | 1,480 | |
| HF-Q-C-01A-20080-H8 | 200 | 80 | 1.5 | 3 | 1,680 | |
| HF-Q-C-01A-200100-H8 | 200 | 100 | 1.5 | 3 | 1,960 | |
| HF-Q-C-01A-200150-H8 | 200 | 150 | 1.5 | 3 | 2,150 | |
| HF-Q-C-01A-25050-H8 | 250 | 50 | 1.5 | 3 | 1,290 | |
| HF-Q-C-01A-25060-H8 | 250 | 60 | 1.5 | 3 | 1,560 | |
| HF-Q-C-01A-25080-H8 | 250 | 80 | 1.5 | 3 | 1,820 | |
| HF-Q-C-01A-250100-H8 | 250 | 100 | 1.5 | 3 | 2,090 | |
| HF-Q-C-01A-250150-H8 | 250 | 150 | 1.5 | 3 | 2,350 | |
| HF-Q-C-01A-30050-H8 | 300 | 50 | 1.5 | 3 | 1,310 | |
| HF-Q-C-01A-30060-H8 | 300 | 60 | 1.5 | 3 | 1,650 | |
| HF-Q-C-01A-30080-H8 | 300 | 80 | 1.5 | 3 | 1,980 | |
| HF-Q-C-01A-300100-H8 | 300 | 100 | 1.5 | 3 | 2,150 | |
| HF-Q-C-01A-300150-H8 | 300 | 150 | 1.5 | 3 | 2,460 | |
| HF-Q-C-01A-30020-H8 | 300 | 200 | 1.5 | 3 | 2,680 | |
| HF-Q-C-01A-40050-H8 | 400 | 50 | 2.0 | 3 | 1,380 | |
| HF-Q-C-01A-40060-H8 | 400 | 60 | 2.0 | 3 | 1,700 | |
| HF-Q-C-01A-40080-H8 | 400 | 80 | 2.0 | 3 | 2,050 | |
| HF-Q-C-01A-400100-H8 | 400 | 100 | 2.0 | 3 | 2,260 | |
| HF-Q-C-01A-400150-H8 | 400 | 150 | 2.0 | 3 | 2,590 | |
| HF-Q-C-01A-400200-H8 | 400 | 200 | 2.0 | 3 | 2,760 | |
| HF-Q-C-01A-50060-H8 | 500 | 60 | 2.0 | 3 | 1,810 | |
| HF-Q-C-01A-50080-H8 | 500 | 80 | 2.0 | 3 | 2,150 | |
| HF-Q-C-01A-500100-H8 | 500 | 100 | 2.0 | 3 | 2,310 | |
| HF-Q-C-01A-500150-H8 | 500 | 150 | 2.0 | 3 | 2,650 | |
| HF-Q-C-01A-500200-H8 | 500 | 200 | 2.0 | 3 | 2,890 | |
| HF-Q-C-01A-60080-H8 | 600 | 80 | 2.0 | 3 | 2,250 | |
| HF-Q-C-01A-600100-H8 | 600 | 100 | 2.0 | 3 | 2,680 | |
| HF-Q-C-01A-600150-H8 | 600 | 150 | 2.0 | 3 | 2,890 | |
| HF-Q-C-01A-600200-H8 | 600 | 200 | 2.0 | 3 | 3,010 | |
| HF-Q-C-01A-800100-H8 | 800 | 100 | 2.5 | 3 | 2,790 | |
| HF-Q-C-01A-800150-H8 | 800 | 150 | 2.5 | 3 | 3,080 | |
| HF-Q-C-01A-800200-H8 | 800 | 200 | 2.5 | 3 | 3,350 |
Series list and declared SWL as printed in SGS reports QDPL2406001066TF-3 / QDPL2406001066TF-6. Suffix -E8 = pre-galvanized, -H8 = post-galvanized (hot-dip); stainless series prefix HF-S6. Declared SWL is the manufacturer's rating listed in the report; the measured load test is shown under Test data.
Covers, dividers and non-standard sizes are made to drawing.
02Test data · SGS
Load-tested at 2,680 N/m over a 1.2 m span.
Type tests to IEC 61537:2023 by SGS-CSTC (Qingdao). Values below are measured results from reports QDPL2406001066TF-3 and QDPL2406001066TF-6.
- Mid-span deflection · galvanized
- 6.17 / 5.77 mm
- W300 / W600 · limit 12 mm (L/100)
- Mid-span deflection · stainless
- 7.20 / 5.76 mm
- W300 / W600 · limit 12 mm
- Transverse deflection · galvanized
- 5.13 / 10.46 mm
- W300 / W600 · limit 15 / 30 mm (W/20)
- Overload 1.7 × SWL
- 4,556 N/m
- No collapse
- Electrical continuity
- 10–15 mΩ
- Limit ≤ 50 mΩ
- Corrosion · post-galvanised
- Class 8 · 85 μm
- IEC 61537 Table 1
- Corrosion · pre-galvanised
- Class 1 · 5.6 μm
- IEC 61537 Table 1
- Temperature
- −5 °C to +40 °C
- Classification range
Metallic · non-flame propagating · electrically continuous · conductive · W300 pre-galvanized 300 × 200, W600 post-galvanized 600 × 100, L 3,000 mm
03Materials & finishes
Choose the finish by the site, not the catalogue.
Each finish below is available for this product line. ISO 9223 classes are general guidance; we confirm the finish against your specification.
01
Pre-galvanized steel
Continuously hot-dip galvanized coil, slit, punched and formed after coating.
Use · Dry interiors: offices, data halls, plant rooms.
ISO 9223C1–C2
SGS (IEC 61537): pre-galvanised class 1, zinc 5.6 μm — ladder, perforated and trunking series. Also the base sheet for our powder-coated trays.
02
Hot-dip galvanized (after fabrication)
Finished sections are dipped in molten zinc after punching and welding, so cut edges, holes and welds are coated.
Use · Outdoor racks, humid process halls, car parks, tunnels.
ISO 9223C3–C4
SGS (IEC 61537): post-galvanised class 8, zinc 85 μm — ladder, perforated and trunking series.
03
ZAM · zinc-aluminium-magnesium
Steel with a zinc-aluminium-magnesium coating, formed after coating. The coating protects cut edges and holes as it weathers.
Use · Humid interiors and sheltered outdoor runs where pre-galvanized sheet is not enough.
ISO 9223C3–C4
04
Electrostatic powder coating
Five-stage pretreatment (degreasing, pickling, surface conditioning and phosphating, multi-stage pure-water rinse, drying at 80–100 °C for 30 min), electrostatic application at 50–100 kV, curing at 180–220 °C for 20–30 min.
Use · Interiors where circuits are colour-coded or appearance matters.
ISO 9223C1–C3
Each batch is sample-tested for cross-cut adhesion, impact and salt spray.
05
Duplex · HDG + powder coat
Powder topcoat over hot-dip galvanizing: barrier protection on top of sacrificial zinc.
Use · Coastal and outdoor runs that also need a colour.
ISO 9223C4–C5
06
Stainless steel 304
Austenitic stainless steel — no coating to damage during installation.
Use · Food, pharma, cleanrooms; general outdoor runs away from chlorides.
ISO 9223Hygienic · C3–C4
07
Stainless steel 316
Molybdenum-bearing stainless grade for chloride and chemical exposure.
Use · Ports, offshore-adjacent plants, refineries, wastewater.
ISO 9223C4–C5 · CX
08
Aluminium alloy
Lightweight, non-magnetic alloy with a natural oxide layer.
Use · Weight-sensitive structures and non-magnetic requirements.
ISO 9223C3–C4
04Fittings & supports
Quote the complete run.
Bends, covers, splice plates and supports in the same material and finish — itemized on one quotation.
Full accessories catalogue05Production & stock
Photographed in our own workshop.
Finished sections in production, stock and export packing at the Liaocheng factory.
06Applications
Where this line is specified.
07Technical documents
Downloads
Datasheet for this line plus the certificates that apply to it.
Download center- Datasheet · PDF · 259 KBCable Trunking datasheetRange, finishes and SGS test data · A4 PDF
- Certificate · PDF · 250 KBCable trunking · Mild steel, zinc coatedSGS QDPL2406001066-3 · IEC 61537:2023
- Test report · PDF · 921 KBCable trunking · Mild steel, zinc coatedSGS QDPL2406001066TF-3 · IEC 61537:2023
- Certificate · PDF · 225 KBCable trunking · Stainless steelSGS QDPL2406001066-6 · IEC 61537:2023
- Test report · PDF · 886 KBCable trunking · Stainless steelSGS QDPL2406001066TF-6 · IEC 61537:2023
- CE attestation · PDF · 31 KBCE · Low Voltage Directive attestationUDEM M.2023.206.C88198 · EN 61537:2007
- ISO certificates · PDF · 5.1 MBISO 9001 · ISO 14001 · ISO 45001Huadingsihai · CNAS C256-M · valid to 2028-07-24
Quote · Trunking
Add cable trunking to your RFQ.
Give sizes, quantities and the finish — or send the cable schedule and drawings by email. No prices are shown online; every quotation is itemized.
- +86 130 2055 8968