02Cable tray system
Perforated Cable Tray
A one-piece perforated base with formed side walls. The continuous floor supports small and mixed cables without sagging, while the perforations keep airflow and accept fixings and drop-outs anywhere along the run.

- Width
- 50–800mm
- Height
- 25–200mm
- Thickness
- 1.0–2.5mm
- Standard length
- 3m
- Tested load
- 2,680N/m
- 1.2 m span · SGS
Materials & finishes
Standard · model series
Sales engineering · +86 130 2055 8968 · arya@globalcabletray.com
01Standard series
Perforated series · IEC 61537:2023
Forty-nine models from 50 × 25 to 800 × 200 mm, as listed in the SGS verification reports. Add any row to your RFQ.
Material
Width (mm)
| Model | W (mm) | H (mm) | t (mm) | L (m) | SWL (N/m) | Add to RFQ |
|---|---|---|---|---|---|---|
| HF-Q-P-01A-5025-H8 | 50 | 25 | 1.0 | 3 | 78 | |
| HF-Q-P-01A-6025-H8 | 60 | 25 | 1.0 | 3 | 92 | |
| HF-Q-P-01A-6040-H8 | 60 | 40 | 1.0 | 3 | 368 | |
| HF-Q-P-01A-6050-H8 | 60 | 50 | 1.0 | 3 | 708 | |
| HF-Q-P-01A-8040-H8 | 80 | 40 | 1.0 | 3 | 491 | |
| HF-Q-P-01A-8050-H8 | 80 | 50 | 1.0 | 3 | 946 | |
| HF-Q-P-01A-8060-H8 | 80 | 60 | 1.0 | 3 | 1,280 | |
| HF-Q-P-01A-10050-H8 | 100 | 50 | 1.2 | 3 | 1,100 | |
| HF-Q-P-01A-10060-H8 | 100 | 60 | 1.2 | 3 | 1,350 | |
| HF-Q-P-01A-10080-H8 | 100 | 80 | 1.2 | 3 | 1,450 | |
| HF-Q-P-01A-100100-H8 | 100 | 100 | 1.2 | 3 | 1,710 | |
| HF-Q-P-01A-15050-H8 | 150 | 50 | 1.5 | 3 | 1,180 | |
| HF-Q-P-01A-15060-H8 | 150 | 60 | 1.5 | 3 | 1,410 | |
| HF-Q-P-01A-15080-H8 | 150 | 80 | 1.5 | 3 | 1,570 | |
| HF-Q-P-01A-150100-H8 | 150 | 100 | 1.5 | 3 | 1,820 | |
| HF-Q-P-01A-20050-H8 | 200 | 50 | 1.5 | 3 | 1,230 | |
| HF-Q-P-01A-20060-H8 | 200 | 60 | 1.5 | 3 | 1,480 | |
| HF-Q-P-01A-20080-H8 | 200 | 80 | 1.5 | 3 | 1,680 | |
| HF-Q-P-01A-200100-H8 | 200 | 100 | 1.5 | 3 | 1,960 | |
| HF-Q-P-01A-200150-H8 | 200 | 150 | 1.5 | 3 | 2,150 | |
| HF-Q-P-01A-25050-H8 | 250 | 50 | 1.5 | 3 | 1,290 | |
| HF-Q-P-01A-25060-H8 | 250 | 60 | 1.5 | 3 | 1,560 | |
| HF-Q-P-01A-25080-H8 | 250 | 80 | 1.5 | 3 | 1,820 | |
| HF-Q-P-01A-250100-H8 | 250 | 100 | 1.5 | 3 | 2,090 | |
| HF-Q-P-01A-250150-H8 | 250 | 150 | 1.5 | 3 | 2,350 | |
| HF-Q-P-01A-30050-H8 | 300 | 50 | 1.5 | 3 | 1,310 | |
| HF-Q-P-01A-30060-H8 | 300 | 60 | 1.5 | 3 | 1,650 | |
| HF-Q-P-01A-30080-H8 | 300 | 80 | 1.5 | 3 | 1,980 | |
| HF-Q-P-01A-300100-H8 | 300 | 100 | 1.5 | 3 | 2,150 | |
| HF-Q-P-01A-300150-H8 | 300 | 150 | 1.5 | 3 | 2,460 | |
| HF-Q-P-01A-30020-H8 | 300 | 200 | 1.5 | 3 | 2,680 | |
| HF-Q-P-01A-40050-H8 | 400 | 50 | 2.0 | 3 | 1,380 | |
| HF-Q-P-01A-40060-H8 | 400 | 60 | 2.0 | 3 | 1,700 | |
| HF-Q-P-01A-40080-H8 | 400 | 80 | 2.0 | 3 | 2,050 | |
| HF-Q-P-01A-400100-H8 | 400 | 100 | 2.0 | 3 | 2,260 | |
| HF-Q-P-01A-400150-H8 | 400 | 150 | 2.0 | 3 | 2,590 | |
| HF-Q-P-01A-400200-H8 | 400 | 200 | 2.0 | 3 | 2,760 | |
| HF-Q-P-01A-50060-H8 | 500 | 60 | 2.0 | 3 | 1,810 | |
| HF-Q-P-01A-50080-H8 | 500 | 80 | 2.0 | 3 | 2,150 | |
| HF-Q-P-01A-500100-H8 | 500 | 100 | 2.0 | 3 | 2,310 | |
| HF-Q-P-01A-500150-H8 | 500 | 150 | 2.0 | 3 | 2,650 | |
| HF-Q-P-01A-500200-H8 | 500 | 200 | 2.0 | 3 | 2,890 | |
| HF-Q-P-01A-60080-H8 | 600 | 80 | 2.0 | 3 | 2,250 | |
| HF-Q-P-01A-600100-H8 | 600 | 100 | 2.0 | 3 | 2,680 | |
| HF-Q-P-01A-600150-H8 | 600 | 150 | 2.0 | 3 | 2,890 | |
| HF-Q-P-01A-600200-H8 | 600 | 200 | 2.0 | 3 | 3,010 | |
| HF-Q-P-01A-800100-H8 | 800 | 100 | 2.5 | 3 | 2,790 | |
| HF-Q-P-01A-800150-H8 | 800 | 150 | 2.5 | 3 | 3,080 | |
| HF-Q-P-01A-800200-H8 | 800 | 200 | 2.5 | 3 | 3,350 |
Series list and declared SWL as printed in SGS reports QDPL2406001066TF-2 / QDPL2406001066TF-5. Suffix -E8 = pre-galvanized, -H8 = post-galvanized (hot-dip); stainless series prefix HF-S6. Declared SWL is the manufacturer's rating listed in the report; the measured load test is shown under Test data.
Non-standard widths, heights, thicknesses and lengths are made to drawing.
02Test data · SGS
Load-tested at 2,680 N/m over a 1.2 m span.
Type tests to IEC 61537:2023 by SGS-CSTC (Qingdao). Values below are measured results from reports QDPL2406001066TF-2 and QDPL2406001066TF-5.
- Mid-span deflection · galvanized
- 6.46 / 5.76 mm
- W300 / W600 · limit 12 mm (L/100)
- Mid-span deflection · stainless
- 6.37 / 6.07 mm
- W300 / W600 · limit 12 mm
- Transverse deflection · galvanized
- 6.43 / 9.75 mm
- W300 / W600 · limit 15 / 30 mm (W/20)
- Overload 1.7 × SWL
- 4,556 N/m
- No collapse
- Electrical continuity
- 10–15 mΩ
- Limit ≤ 50 mΩ
- Corrosion · post-galvanised
- Class 8 · 85 μm
- IEC 61537 Table 1
- Corrosion · pre-galvanised
- Class 1 · 5.6 μm
- IEC 61537 Table 1
- Temperature
- −5 °C to +40 °C
- Classification range
Metallic · non-flame propagating · electrically continuous · conductive · W300 pre-galvanized 300 × 200, W600 post-galvanized 600 × 100, L 3,000 mm
03Materials & finishes
Choose the finish by the site, not the catalogue.
Each finish below is available for this product line. ISO 9223 classes are general guidance; we confirm the finish against your specification.
01
Pre-galvanized steel
Continuously hot-dip galvanized coil, slit, punched and formed after coating.
Use · Dry interiors: offices, data halls, plant rooms.
ISO 9223C1–C2
SGS (IEC 61537): pre-galvanised class 1, zinc 5.6 μm — ladder, perforated and trunking series. Also the base sheet for our powder-coated trays.
02
Hot-dip galvanized (after fabrication)
Finished sections are dipped in molten zinc after punching and welding, so cut edges, holes and welds are coated.
Use · Outdoor racks, humid process halls, car parks, tunnels.
ISO 9223C3–C4
SGS (IEC 61537): post-galvanised class 8, zinc 85 μm — ladder, perforated and trunking series.
03
ZAM · zinc-aluminium-magnesium
Steel with a zinc-aluminium-magnesium coating, formed after coating. The coating protects cut edges and holes as it weathers.
Use · Humid interiors and sheltered outdoor runs where pre-galvanized sheet is not enough.
ISO 9223C3–C4
04
Electrostatic powder coating
Five-stage pretreatment (degreasing, pickling, surface conditioning and phosphating, multi-stage pure-water rinse, drying at 80–100 °C for 30 min), electrostatic application at 50–100 kV, curing at 180–220 °C for 20–30 min.
Use · Interiors where circuits are colour-coded or appearance matters.
ISO 9223C1–C3
Each batch is sample-tested for cross-cut adhesion, impact and salt spray.
05
Duplex · HDG + powder coat
Powder topcoat over hot-dip galvanizing: barrier protection on top of sacrificial zinc.
Use · Coastal and outdoor runs that also need a colour.
ISO 9223C4–C5
06
Stainless steel 304
Austenitic stainless steel — no coating to damage during installation.
Use · Food, pharma, cleanrooms; general outdoor runs away from chlorides.
ISO 9223Hygienic · C3–C4
07
Stainless steel 316
Molybdenum-bearing stainless grade for chloride and chemical exposure.
Use · Ports, offshore-adjacent plants, refineries, wastewater.
ISO 9223C4–C5 · CX
08
Aluminium alloy
Lightweight, non-magnetic alloy with a natural oxide layer.
Use · Weight-sensitive structures and non-magnetic requirements.
ISO 9223C3–C4
04Fittings & supports
Quote the complete run.
Bends, covers, splice plates and supports in the same material and finish — itemized on one quotation.
Full accessories catalogue05Production & stock
Photographed in our own workshop.
Finished sections in production, stock and export packing at the Liaocheng factory.
06Applications
Where this line is specified.
- 01Data centers & telecomPower distribution where cables need continuous support.Pre-galvanized steel
- 02Coastal & high-corrosionExposed runs on jetties, terminals and coastal plants.Stainless steel 316
- 03Power, solar & storageString and control cabling on shorter spans.ZAM · zinc-aluminium-magnesium
- 04Industrial plantsGeneral power and control runs.Pre-galvanized steel
07Technical documents
Downloads
Datasheet for this line plus the certificates that apply to it.
Download center- Datasheet · PDF · 302 KBPerforated Cable Tray datasheetRange, finishes and SGS test data · A4 PDF
- Certificate · PDF · 251 KBPerforated cable tray · Mild steel, zinc coatedSGS QDPL2406001066-2 · IEC 61537:2023
- Test report · PDF · 921 KBPerforated cable tray · Mild steel, zinc coatedSGS QDPL2406001066TF-2 · IEC 61537:2023
- Certificate · PDF · 224 KBPerforated cable tray · Stainless steelSGS QDPL2406001066-5 · IEC 61537:2023
- Test report · PDF · 886 KBPerforated cable tray · Stainless steelSGS QDPL2406001066TF-5 · IEC 61537:2023
- CE attestation · PDF · 31 KBCE · Low Voltage Directive attestationUDEM M.2023.206.C88198 · EN 61537:2007
- ISO certificates · PDF · 5.1 MBISO 9001 · ISO 14001 · ISO 45001Huadingsihai · CNAS C256-M · valid to 2028-07-24
Quote · Perforated
Add perforated cable tray to your RFQ.
Give sizes, quantities and the finish — or send the cable schedule and drawings by email. No prices are shown online; every quotation is itemized.
- +86 130 2055 8968







