Two formed side rails joined by welded, slotted rungs. The open construction carries large power cables over long support spans, lets heat escape and gives a clamping point at every rung.

Datasheet PDF
Hot-dip galvanized ladder cable tray section with welded slotted rungs
01 / HF-Q-T-01AHot-dip galvanized
Width
50–800mm
Height
25–200mm
Thickness
1.0–2.5mm
Standard length
3m
Tested load
2,680N/m
1.2 m span · SGS

Materials & finishes

Pre-galvHDGZAMPowder coatHDG + powderSS 304 / 316Aluminium

Standard · model series

IEC 61537:2023 · SGSHF-Q-T-01A · HF-S6-T-01A

Sales engineering · +86 130 2055 8968 · arya@globalcabletray.com

01Standard series

Ladder series · IEC 61537:2023

Forty-nine models from 50 × 25 to 800 × 200 mm, as listed in the SGS verification reports. Add any row to your RFQ.

Material

Width (mm)

ModelW (mm)H (mm)t (mm)L (m)SWL (N/m)Add to RFQ
HF-Q-T-01A-5025-H850251.0378
HF-Q-T-01A-6025-H860251.0392
HF-Q-T-01A-6040-H860401.03368
HF-Q-T-01A-6050-H860501.03708
HF-Q-T-01A-8040-H880401.03491
HF-Q-T-01A-8050-H880501.03946
HF-Q-T-01A-8060-H880601.031,280
HF-Q-T-01A-10050-H8100501.231,100
HF-Q-T-01A-10060-H8100601.231,350
HF-Q-T-01A-10080-H8100801.231,450
HF-Q-T-01A-100100-H81001001.231,710
HF-Q-T-01A-15050-H8150501.531,180
HF-Q-T-01A-15060-H8150601.531,410
HF-Q-T-01A-15080-H8150801.531,570
HF-Q-T-01A-150100-H81501001.531,820
HF-Q-T-01A-20050-H8200501.531,230
HF-Q-T-01A-20060-H8200601.531,480
HF-Q-T-01A-20080-H8200801.531,680
HF-Q-T-01A-200100-H82001001.531,960
HF-Q-T-01A-200150-H82001501.532,150
HF-Q-T-01A-25050-H8250501.531,290
HF-Q-T-01A-25060-H8250601.531,560
HF-Q-T-01A-25080-H8250801.531,820
HF-Q-T-01A-250100-H82501001.532,090
HF-Q-T-01A-250150-H82501501.532,350
HF-Q-T-01A-30050-H8300501.531,310
HF-Q-T-01A-30060-H8300601.531,650
HF-Q-T-01A-30080-H8300801.531,980
HF-Q-T-01A-300100-H83001001.532,150
HF-Q-T-01A-300150-H83001501.532,460
HF-Q-T-01A-30020-H83002001.532,680
HF-Q-T-01A-40050-H8400502.031,380
HF-Q-T-01A-40060-H8400602.031,700
HF-Q-T-01A-40080-H8400802.032,050
HF-Q-T-01A-400100-H84001002.032,260
HF-Q-T-01A-400150-H84001502.032,590
HF-Q-T-01A-400200-H84002002.032,760
HF-Q-T-01A-50060-H8500602.031,810
HF-Q-T-01A-50080-H8500802.032,150
HF-Q-T-01A-500100-H85001002.032,310
HF-Q-T-01A-500150-H85001502.032,650
HF-Q-T-01A-500200-H85002002.032,890
HF-Q-T-01A-60080-H8600802.032,250
HF-Q-T-01A-600100-H86001002.032,680
HF-Q-T-01A-600150-H86001502.032,890
HF-Q-T-01A-600200-H86002002.033,010
HF-Q-T-01A-800100-H88001002.532,790
HF-Q-T-01A-800150-H88001502.533,080
HF-Q-T-01A-800200-H88002002.533,350

Series list and declared SWL as printed in SGS reports QDPL2406001066TF-1 / QDPL2406001066TF-4. Suffix -E8 = pre-galvanized, -H8 = post-galvanized (hot-dip); stainless series prefix HF-S6. Declared SWL is the manufacturer's rating listed in the report; the measured load test is shown under Test data.

Made to order up to W 1,200 mm, side rail height 25–300 mm, lengths 2–9 m and thickness 0.6–3.0 mm.

02Test data · SGS

Load-tested at 2,680 N/m over a 1.2 m span.

Type tests to IEC 61537:2023 by SGS-CSTC (Qingdao). Values below are measured results from reports QDPL2406001066TF-1 and QDPL2406001066TF-4.

Mid-span deflection · galvanized
4.62 / 8.01 mm
W300 / W600 · limit 12 mm (L/100)
Mid-span deflection · stainless
3.66 / 3.05 mm
W300 / W600 · limit 12 mm
Transverse deflection · galvanized
0.71 / 1.82 mm
W300 / W600 · limit 15 / 30 mm (W/20)
Overload 1.7 × SWL
4,556 N/m
No collapse
Electrical continuity
10–15 mΩ
Limit ≤ 50 mΩ
Corrosion · post-galvanised
Class 8 · 85 μm
IEC 61537 Table 1
Corrosion · pre-galvanised
Class 1 · 5.6 μm
IEC 61537 Table 1
Temperature
−5 °C to +40 °C
Classification range

Metallic · non-flame propagating · electrically continuous · conductive · W300 pre-galvanized 300 × 200, W600 post-galvanized 600 × 100, L 3,000 mm

  • QDPL2406001066-1

    Cable ladder

    Mild steel, zinc coated

    IEC 61537:2023 · issued 2024-08-07

    Shandong Hongfeng Electric Group Co., Ltd.

  • QDPL2406001066-4

    Cable ladder

    Stainless steel

    IEC 61537:2023 · issued 2024-08-07

    Shandong Hongfeng Electric Group Co., Ltd.

03Materials & finishes

Choose the finish by the site, not the catalogue.

Each finish below is available for this product line. ISO 9223 classes are general guidance; we confirm the finish against your specification.

  • 01

    Pre-galvanized steel

    Continuously hot-dip galvanized coil, slit, punched and formed after coating.

    Use · Dry interiors: offices, data halls, plant rooms.

    ISO 9223C1–C2

    SGS (IEC 61537): pre-galvanised class 1, zinc 5.6 μm — ladder, perforated and trunking series. Also the base sheet for our powder-coated trays.

  • 02

    Hot-dip galvanized (after fabrication)

    Finished sections are dipped in molten zinc after punching and welding, so cut edges, holes and welds are coated.

    Use · Outdoor racks, humid process halls, car parks, tunnels.

    ISO 9223C3–C4

    SGS (IEC 61537): post-galvanised class 8, zinc 85 μm — ladder, perforated and trunking series.

  • 03

    ZAM · zinc-aluminium-magnesium

    Steel with a zinc-aluminium-magnesium coating, formed after coating. The coating protects cut edges and holes as it weathers.

    Use · Humid interiors and sheltered outdoor runs where pre-galvanized sheet is not enough.

    ISO 9223C3–C4

  • 04

    Electrostatic powder coating

    Five-stage pretreatment (degreasing, pickling, surface conditioning and phosphating, multi-stage pure-water rinse, drying at 80–100 °C for 30 min), electrostatic application at 50–100 kV, curing at 180–220 °C for 20–30 min.

    Use · Interiors where circuits are colour-coded or appearance matters.

    ISO 9223C1–C3

    Each batch is sample-tested for cross-cut adhesion, impact and salt spray.

  • 05

    Duplex · HDG + powder coat

    Powder topcoat over hot-dip galvanizing: barrier protection on top of sacrificial zinc.

    Use · Coastal and outdoor runs that also need a colour.

    ISO 9223C4–C5

  • 06

    Stainless steel 304

    Austenitic stainless steel — no coating to damage during installation.

    Use · Food, pharma, cleanrooms; general outdoor runs away from chlorides.

    ISO 9223Hygienic · C3–C4

  • 07

    Stainless steel 316

    Molybdenum-bearing stainless grade for chloride and chemical exposure.

    Use · Ports, offshore-adjacent plants, refineries, wastewater.

    ISO 9223C4–C5 · CX

  • 08

    Aluminium alloy

    Lightweight, non-magnetic alloy with a natural oxide layer.

    Use · Weight-sensitive structures and non-magnetic requirements.

    ISO 9223C3–C4

All finishes compared

04Fittings & supports

Quote the complete run.

Bends, covers, splice plates and supports in the same material and finish — itemized on one quotation.

Full accessories catalogue

05Production & stock

Photographed in our own workshop.

Finished sections in production, stock and export packing at the Liaocheng factory.

Quote · Ladder

Add ladder cable tray to your RFQ.

Give sizes, quantities and the finish — or send the cable schedule and drawings by email. No prices are shown online; every quotation is itemized.